Winter Electrical Checklist for Commercial and Industrial Facilities

Licensed electrician working in a commercial switchboard

Cold weather is hard on electrical systems. Heating loads peak, exterior equipment faces snow and ice, and an outage at the wrong moment can stop production or close a store. Use this checklist to get your building ready before winter sets in.

1. Exterior and parking lot lighting

With shorter days, your exterior lights run longer and matter more for safety and security. Replace failed fixtures, check photocells and timers so lights come on at dusk, and consider an LED retrofit for older parking lot and wall-pack lighting.

2. Heat tracing and freeze protection

Heat trace cables protect water lines, sprinkler piping and drains from freezing. Test them before the first hard frost: a failed circuit is often only discovered when a pipe bursts.

3. Heaters and make-up air

  • Check unit heaters, electric heaters and make-up air units before you need them.
  • Make sure circuits are not overloaded as heaters are added in docks and workshops.
  • Stagger start-up of large heating loads where possible to limit peak demand.

4. Backup power

Test your standby generator under load, check the transfer switch and confirm fuel supply. Make sure critical loads such as servers, refrigeration, sump pumps and security systems are on backup power. See backup power solutions.

5. Emergency lighting and exit signs

Emergency lighting has to work when the power fails. Test the units, replace weak batteries and confirm coverage still suits your layout.

6. Rooftop and exterior equipment

  • Keep rooftop disconnects accessible and clear of snow.
  • Check exterior boxes, receptacles and enclosures for damaged covers that let in water.
  • Make sure block heater outlets for fleet vehicles are GFCI-protected and working.

7. Panels and connections

Heating season is when weak connections and overloaded panels show up. A maintenance check of panels, breakers and connections before peak load can prevent a mid-winter failure. See commercial repairs and maintenance and industrial troubleshooting.

8. Have an emergency plan

Know where your main disconnects are, keep an up-to-date panel directory, and keep an electrician’s 24/7 number where staff can find it. Our emergency electricians are available 24/7, 365 days a year (after-hours rates apply).

Quick checklist

  • Exterior and parking lot lights working, timers and photocells set
  • Heat tracing tested
  • Heaters and make-up air checked
  • Generator tested under load
  • Emergency lighting tested
  • Rooftop and exterior equipment checked
  • Panels and connections inspected
  • Emergency contacts posted

Related services

Talk to a licensed electrical contractor

North York Electrical Inc. has served businesses, facilities and homeowners across the Greater Toronto Area since 1996. We are ESA-licensed (#7011426), insured and WSIB-covered, estimates are free, and we offer 24/7 emergency service, 365 days a year. Call (647) 990-2696 or send us your project details.

Facebook
Twitter
LinkedIn
Email